[1] |
WHITING SJ,LANGLOIS KA,VATANPARAST H,et al.The vitamin D status of Canadians relative to the 2011 Dietary Reference Intakes: an examination in children and adults with and without supplement use[J].Am J Clin Nutr, 2011,94(1):128-135.
|
[2] |
AUTIER P,GANDINI S.VITAMIN D supplementation and total mortality: a meta-analysis of randomized controlled trials[J]. Arch Intern Med,2007,167(16):1730-1737.
|
[3] |
PETERLIK M,GRANT WB,CROSS HS.Calcium,vitamin D and cancer[J]. Anticancer Res,2009,29(9):3687-3698.
|
[4] |
PEIRIS AN,BAILEY B,MANNING T,et al.Testing for vitamin D deficiency in veterans-is there a seasonal bias[J]. J Am Med Dir Assoc,2010,11(2):128-131.
|
[5] |
PIEPER CF,COLON-EMERIC C,CAMINIS J,et al.Distribution and correlates of serum 25-hydroxyvitamin D levels in a sample of patients with hip fracture[J]. Am J Geriatr Pharmacother,2007,5(4):335-340.
|
[6] |
SOUBERBIELLE JC,BODY JJ,LAPPE JM,et al.Vitamin D and musculoskeletal health,cardiovascular disease,autoimmunity and cancer: recommendations for clinical practice[J].Autoimmun Rev,2010,9(11):709-715.
|
[7] |
SOKOL SI,TSANG P,AGGARWAL V,et al.Vitamin D status and risk of cardiovascular events: lessons learned via systematic review and meta-analysis[J].Cardiol Rev,2011,19(4):192-201.
|
[8] |
HEIJBOER AC,BLANKENSTEIN MA,KEMA IP,et al.Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration[J]. Clin Chem,2012,58(3):543-548.
|
[9] |
CAVALIER E,CARLISI A,BEKAERT AC,et al.Analytical evaluation of the new Abbott Architect 25-OH vitamin D assay[J]. Clin Biochem,2012,45(6):505-508.
|
[10] |
LEINO A,TURPEINEN U,KOSKINEN P.Automated measurement of 25-OH vitamin D3 on the Roche Modular E170 analyzer[J]. Clin Chem,2008,54(12):2059-2062.
|
[11] |
FARRELL CJ,MARTIN S,MCWHINNEY B,et al.State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods[J].Clin Chem,2012,58(3):531-542.
|
[12] |
SNELLMAN G,MELHUS H,GEDEBORG R,et al.Determining vitamin D status: a comparison between commercially available assays[J]. PLoS One,2010,5(7):e11555.
|
[13] |
STEPMAN HC,VANDERROOST A,VAN UYTFANGHE K,et al.Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry[J]. Clin Chem,2011,57(3):441-448.
|
[14] |
TAI SS,BEDNER M,PHINNEY KW.Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry[J]. Anal Chem,2010,82(5):1942-1948.
|
[15] |
VOGESER M,KYRIATSOULIS A,HUBER E,et al.Candidate reference method for the quantification of circulating 25-hydroxyvitamin D3 by liquid chromatography-tandem mass spectrometry[J]. Clin Chem,2004,50(8):1415-1417.
|
[16] |
Food and Drug Administration. Guidance for industry bioanalytical method validation[R]. Rockville:FDA, 2001.
|
[17] |
CARTER GD.25-hydroxyvitamin D: a difficult analyte[J]. Clin Chem,2012,58(3):486-488.
|
[18] |
SHAH I, PETROCZI A,NAUGHTON DP.Method for simultaneous analysis of eight analogues of vitamin D using liquid chromatography tandem mass spectrometry[J]. Chem Cent J,2012,6(1):112.
|
[19] |
CLUSE ZN,FUDGE AN,WHITING MJ,et al.Evaluation of 25-hydroxy vitamin D assay on the immunodiagnostic systems iSYS analyser[J]. Ann Clin Biochem,2012, 49(Pt 2):159-165.
|
[20] |
CHEN Y,KINNEY L, BOŽOVIC A, et al. Performance evaluation of Siemens ADVIA Centaur and Roche MODULAR Analytics E170 total 25-OH vitamin D assays[J]. Clin Biochem, 2012, 45(16-17):1485-1490.
|
[21] |
HSU SA,SOLDO J, GUPTA M.Evaluation of two automated immunoassays for 25-OH vitamin D: comparison against LC-MS/MS[J]. J Steroid Biochem Mol Biol,2013,136:139-145.
|
[22] |
HERRMANN M,HARWOOD T,GASTON-PARRY O,et al.A new quantitative LC tandem mass spectrometry assay for serum 25-hydroxy vitamin D[J]. Steroids,2010,75(13-14):1106-1112.
|