检验医学 ›› 2014, Vol. 29 ›› Issue (1): 31-33.DOI: 10.3969/j.issn.1673-8640.2014.01.007

• 临床应用研究·论著 • 上一篇    下一篇

上海地区成人网织红细胞参数参考区间调查

金硕1, 戴珉2, 张军1, 杨滟3, 沈薇1, 应春妹1, 范竹萍2   

  1. 1.上海交通大学医学院附属仁济医院检验科, 上海 200127;
    2.上海交通大学医学院附属仁济医院体检中心, 上海 200127;
    3.上海安图医院检验科, 上海 200093
  • 收稿日期:2013-05-05 出版日期:2014-01-20 发布日期:2014-01-20
  • 通讯作者: 沈 薇, 联系电话:021-68383300。
  • 作者简介:金 硕, 男, 1988生, 技士, 主要从事临床检验工作。

Reference ranges of reticulocyte parameters of adults in Shanghai

JIN Shuo1, DAI Min2, ZHANG Jun1, YANG Yan3, SHEN Wei1, YING Chunmei1, FAN Zhuping2.   

  1. 1.Department of Clinical Laboratory, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200127, China; 2.Department of Physical Examination Center, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200127, China; 3.Department of Clinical Laboratory, Antu Hospital, Shanghai 200093, China
  • Received:2013-05-05 Online:2014-01-20 Published:2014-01-20

摘要: 目的 调查上海地区成人网织红细胞绝对值(RET#)和百分比(RET%)及分群值的参考区间。方法 采用XE-2100全自动血液分析仪检测2 000名体检者(男1 116名, 女884名)网织红细胞及其相关参数。采集所有对象乙二胺四乙酸二钾(EDTA-K2)抗凝静脉全血2 mL, 2 h内完成检测。数据使用SPSS11.0软件进行统计分析。结果 RET%的参考区间:男 (0.61~1.87)%, 女 (0.60~1.81)%;RET#的参考区间:男 (0.030~0.096)×1012/L, 女(0.025~0.082)×1012/L;低荧光网织红细胞比率(LFR)、中荧光网织红细胞比率(MFR)、高荧光网织红细胞比率(HFR)的参考区间男性分别为(80.8~97.1)%、(2.8~18.1)%、(0.0~2.3)%;女性分别为(82.3~97.9)%、(2.0~15.9)%、(0.0~1.8)%。不同年龄组间RET#和RET%差异无统计学意义(P=0.138和P=0.061), 分群参数差异有统计学意义(P<0.01)。结果 建立了上海地区成人仪器法检测网织红细胞相关参数的参考区间, 提高了网织红细胞检测的临床利用价值。

关键词: 网织红细胞, 参考区间, 全自动血液分析仪

Abstract: Objective To investigate the reference ranges of reticulocyte absolute value(RET#) and percentage(RET%) and its grouping parameters of adults in Shanghai. Methods By XE-2100 automatic hematology analyzer, the reticulocyte and it relative parameters were determined among 2 000 healthy subjects. There were 1 116 males and 884 females. A total of 2mL venous whole blood samples were collected for anticoagulation by ethylene diamine tetraacetic acid-dipotassium (EDTA-K2). The samples were determined within 2h after collection. Statistical analysis was performed by SPSS11.0 software. Results The reference ranges of RET% were (0.61-1.87)% in males and (0.60-1.81)% in females, respectively. The RET# were (0.030-0.096)×1012/L in males and (0.025-0.082)×1012/L in females. The retios for low fluorescent reticulocyte(LFR), middle fluorescent reticulocyte(MFR) and high fluorescent reticulocyte(HFR) were (80.8-97.1)%, (2.8-18.1)% and (0.0-2.3)% in males and(82.3-97.9)%, (2.0-15.9)% and (0.0-1.8)% in females, respectively. By classifying the healthy subjects as age, there was no statistical significance in RET# and RET% (P=0.138 and P=0.061). However, there was statistical significance for grouping parameters (P<0.01). Results The reference ranges of reticulocyte parameters are established for adults in Shanghai. The clinical application significance of reticulocyte parameter determination is improved.

Key words: Reticulocyte, Reference range, Automatic hematology analyzer

中图分类号: