检验医学 ›› 2025, Vol. 40 ›› Issue (6): 560-564.DOI: 10.3969/j.issn.1673-8640.2025.06.008

• 论著 • 上一篇    下一篇

不同革兰阴性菌感染老年重症肺炎患者凝血功能变化及其临床意义

杨琦, 林英, 郭楠, 栗晓彬, 尚峨, 李洪敏, 姚兴伟()   

  1. 北京中医药大学东直门医院检验科,北京 100700
  • 收稿日期:2023-02-16 修回日期:2024-12-13 出版日期:2025-06-30 发布日期:2025-07-01
  • 通讯作者: 姚兴伟
  • 作者简介:姚兴伟,E-mail: yaoxingwei765@163.com
    杨 琦,女,1982年生,学士,副主任技师,主要从事临床生物化学检验工作。
  • 基金资助:
    北京中医药大学基本科研面上项目(2016-JYB-JSMS-035)

Changes of coagulation function in elderly patients with severe pneumonia infected by different Gram-negative bacteria

YANG Qi, LIN Ying, GUO Nan, LI Xiaobin, SHANG E, LI Hongmin, YAO Xingwei()   

  1. Department of Clinical Laboratory,Dongzhimen Hospital,Beijing University of Chinese Medicine,Beijing 100700,China
  • Received:2023-02-16 Revised:2024-12-13 Online:2025-06-30 Published:2025-07-01
  • Contact: YAO Xingwei

摘要:

目的 观察不同革兰阴性菌感染老年重症肺炎患者凝血功能变化情况,为临床诊疗提供参考。方法 选取2019年9月—2022年9月北京中医药大学东直门医院197例老年重症肺炎患者。于抗菌药物治疗前,取患者痰液进行病原菌培养,并检测患者凝血功能。根据疾病转归将革兰阴性菌感染患者分为预后不良组和预后良好组。比较革兰阴性菌感染者和革兰阳性菌感染者凝血功能指标[活化部分凝血活酶时间(APTT)、凝血酶原时间(PT)、凝血酶时间(TT)、D-二聚体(DD)、纤维蛋白原(Fib)]差异;比较不同革兰阴性菌感染患者凝血功能差异;比较不同预后革兰阴性菌感染重症肺炎患者凝血功能差异。结果 197例患者中,痰培养阳性155例,其中革兰阴性菌感染者110例(70.97%)。革兰阳性菌感染者APTT短于痰培养阴性者,DD水平高于痰培养阴性者(P<0.05);革兰阴性菌感染者 APTT、PT短于痰培养阴性者、革兰阳性菌感染者,DD、Fib水平高于痰培养阴性者和革兰阳性菌感染者(P<0.05)。鲍曼不动杆菌感染者APTT、PT值短于其他类型革兰阴性菌感染者,DD、Fib水平高于其他类型革兰阴性菌感染者(P<0.05);预后不良组APTT、PT短于预后良好组,DD、Fib水平高于预后良好组(P<0.05)。结论 革兰阴性菌感染老年重症肺炎患者存在凝血功能紊乱,以鲍曼不动杆菌感染患者凝血功能紊乱情况较为明显;凝血功能紊乱与患者预后不良有一定的关系。

关键词: 凝血功能, 重症肺炎, 老年人, 革兰阴性菌

Abstract:

Objective To observe the changes of coagulation function in elderly patients with severe pneumonia infected by different Gram-negative bacteria,and to provide a reference for clinical diagnosis and treatment. Methods A total of 197 elderly patients with severe pneumonia in Dongzhimen Hospital of Beijing University of Chinese Medicine from September 2019 to September 2022 were enrolled. Before the treatment with antibacterial drugs,the sputum samples were taken for pathogen culture. The coagulation function was determined. The differences in coagulation function indicators [activated partial thromboplastin time(APTT),prothrombin time(PT),thrombin time(TT),D-dimer(DD),plasma fibrinogen(Fib)] were compared between patients infected with Gram-negative bacteria and those infected with Gram-positive bacteria. Based on the disease outcome,patients infected with Gram-negative bacteria were classified into poor and good prognosis groups. The differences in coagulation function among patients infected with different Gram-negative bacteria were compared. The differences in coagulation function among patients with severe pneumonia infected by Gram-negative bacteria with different prognoses were evaluated. Results Among the 197 patients,110(55.84%)cases were infected with Gram-negative bacteria. The APTT of patients infected with Gram-positive bacteria was shorter than that with negative sputum culture,and the DD level was higher(P<0.05). The APTT and PT of patients infected with Gram-negative bacteria were shorter than those with negative sputum culture and Gram-positive bacteria,while the DD and Fib levels were higher than those with negative sputum culture and Gram-positive bacteria(P<0.05). The APTT and PT of patients infected with Acinetobacter baumannii were shorter than those of patients infected with other types of Gram-negative bacteria,while the levels of DD and Fib were higher than those of patients infected with other types of Gram-negative bacteria(P<0.05). The APTT and PT in poor prognosis group were shorter than those in good prognosis group,and the levels of DD and Fib were higher than those in good prognosis group(P<0.05). Conclusions Elderly patients with severe pneumonia infected by Gram-negative bacteria have coagulation dysfunction,and the coagulation dysfunction is more obvious in patients infected with Acinetobacter baumannii. There is a certain relationship between poor coagulation function and poor prognosis of patients.

Key words: Coagulation function, Severe pneumonia, Elderly, Gram-negative bacterium

中图分类号: