检验医学 ›› 2018, Vol. 33 ›› Issue (2): 127-131.DOI: 10.3969/j.issn.1673-8640.2018.02.008

• 技术研究与评价_论著 • 上一篇    下一篇

ICP-MS测定全血中5种微量元素及其参考区间的建立

徐凤仙, 于嘉屏, 吴娟娟   

  1. 上海迪安医学检验所研发实验室,上海 200433;
  • 收稿日期:2017-03-06 出版日期:2018-02-28 发布日期:2018-03-02
  • 作者简介:null

    作者简介:徐凤仙,男,1983年生, 硕士,主要从事色谱和质谱分析工作。

Determinations of 5 kinds of trace elements by ICP-MS and establishment of reference intervals

XU Fengxian, YU Jiaping, WU Juanjuan   

  1. Research and Development Laboratory, Shanghai Di'an Medical Testing Institute,Shanghai 200433,China;
  • Received:2017-03-06 Online:2018-02-28 Published:2018-03-02

摘要:

目的 建立同时测定全血中铁(Fe)、镁(Mg)、钙(Ca)、锌(Zn)、铜(Cu)的电感耦合等离子体质谱(ICP-MS)方法。方法 将全血样本混匀后用含Triton 100的稀硝酸溶液进行50倍稀释,以锗(Ge)元素为内标,建立ICP-MS检测全血Fe、Mg、Ca、Zn、Cu的方法。收集495名体检健康者全血样本,按性别和年龄(≤16岁和>16岁)分别分组比较并建立5种元素的参考区间。结果 5种元素的标准曲线线性均良好(r值为0.999 6~1.000 0),批内精密度为0.31%~3.62%,批间精密度为1.37%~7.15%,添加回收率为98.2%~112.7%。正常人群、男女性之间全血Fe、Mg、Ca、Zn、Cu水平差异均无统计学意义(P>0.05),而≤16岁组与>16岁组之间5种元素差异均有统计学意义(P<0.05)。按年龄以x±2s方式建立参考区间:≤16岁者Mg为30.2~43.4 mg/L、Ca为47.2~69.6 mg/L、Fe为320.6~466.0 mg/L、Cu为0.64 ~1.36 mg/L、Zn为3.1~6.8 mg/L;>16岁者Mg为27.0~43.6 mg/L、Ca为42.6~64.6 mg/L、Fe为275.2~530.3 mg/L、Cu为0.40~1.58 mg/L、Zn为4.3~8.3 mg/L。结论 建立的ICP-MS方法可同时测定Fe、Mg、Ca、Zn、Cu,敏感性高,操作简便、稳定,准确度高,可用于临床大样本分析。

关键词: 铁, 镁, 钙, 锌, 铜, 电感耦合等离子体质谱, 全血

Abstract:

Objective To establish an inductively coupled plasma mass spectrometry(ICP-MS) for the determinations of 5 kinds of trace elements [iron(Fe),magnesium(Mg),calcium(Ca),zinc(Zn) and copper(Cu)] in whole blood. Methods After whole blood samples were fully mixed and diluted to 50 times with the solution containing Triton 100 and dilute nitric acid,adding germanium(Ge) as internal standard,an ICP-MS was established for determining 5 kinds of trace elements. A total of 495 whole blood samples of healthy subjects were collected. According to sex and age(≤16 years old and >16 years old groups),the reference intervals were established. Results The standard curve linearities were good for 5 kinds of trace elements(r=0.999 6-1.000 0). The within-run precision was 0.31%-3.62%,and the between-run precision was 1.37%-7.15%. The recovery rate was 98.2% -112.7 %. Each element had no statistical significance between males and females(P>0.05),but there was statistical significance between ≤16 years old and >16 years old groups(P<0.05). The reference intervals(x±2s) in ≤16 years old group were 30.2-43.4 mg/L for Mg,47.2-69.6 mg/L for Ca,320.6-466.0 mg/L for Fe,0.64 -1.36 mg/L for Cu and 3.1-6.8 mg/L for Zn,and those in >16 years old group were 27.0-43.6 mg/L,42.6-64.6 mg/L,275. 2-530.3 mg/L,0.40-1.58 mg/L and 4.3- 8.3 mg/L,respectively. Conclusions ICP-MS can determine Fe,Mg,Ca,Zn and Cu in whole blood simultaneously,with sensitivity,simple operation,stability and accuracy.

Key words: Iron, Magnesium, Calcium, Zinc, Copper, Inductively coupled plasma mass spectrometry, Whole blood