Analysis on the influencefactors of determining mitochondrial aspartate aminotransferase by immune suppression method

  

  1. Department of Clinical Laboratory,Changzhou Tumor Hospital Affiliated to Soochow University,Jiangsu Changzhou 213001,China
  • Online:2012-12-30 Published:2012-12-04

Abstract: Objective To investigate the influence factors of determining serum mitochondrial aspartate aminotransferase(m-AST) by immune suppression method.   Methods The determinations of m-AST and aspartate aminotransferase(AST) in a control group(48 cases with AST≤50 U/L) and a hepatitis group(60 patients with hepatitis) were performed by immune suppression method and enzyme hydrolysis method respectively,and then the m-AST/AST ratios were calculated. The deficiency of cytosolic aspartate aminotransferase(c-AST) antibody in the immune suppression method reagents was confirmed through the complementary c-AST antibody test. Results In the control group,the m-AST value by immune suppression method was significantly higher than that by enzyme hydrolysis method(P<0.01),while in the hepatitis group,the m-AST value by immune suppression method was significantly lower than that by enzyme hydrolysis method(P<0.01). By the immune suppression method,the m-AST/AST ratio had no significant difference between the control group and the hepatitis group(P=0.094). By the enzyme hydrolysis method,the m-AST/AST ratio in the hepatitis group was significantly higher than that in the control group(P<0.01). The correlation of m-AST and AST in the hepatitis group(r=0.969) was higher than that in the control group by immune suppression method(r=0.878),while by the enzyme hydrolysis method,the correlation in the hepatitis group(r=0.856) was lower than thatin the control group(r=0.902). In the complementary c-AST antibody test of immune suppression method,the values of m-AST decreased with the increase of c-AST antibody being added. Conclusions If the c-AST antibody is not enough in the immune suppression method reagents,c-AST could notbe inhibited completely,which would cause the decline of the specificity of m-AST test. Using the m-AST/AST ratio,the severity of the liver disease can be analyzed. The antibody concentration of m-AST reagent,the antibody stabilizers and so on should be standardized in order to contribute to the quality control work and improve the clinical application significance of m-AST.

Key words: Aspartate aminotransferase, Mitochondrial isoenzyme, Immune suppression method, Enzyme hydrolysis method, Antibody