Laboratory Medicine ›› 2015, Vol. 30 ›› Issue (2): 102-107.DOI: 10.3969/j.issn.1673-8640.2015.02.002
• Orignal Article • Previous Articles Next Articles
DAI Yingxin, LI Min
Received:
2014-10-24
Online:
2015-02-28
Published:
2015-02-12
CLC Number:
DAI Yingxin, LI Min. Application of MALDI-TOF MS technology in clinical microbial determination[J]. Laboratory Medicine, 2015, 30(2): 102-107.
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.shjyyx.com/EN/10.3969/j.issn.1673-8640.2015.02.002
[1] | DEKKER JP, BRANDAJ A.MALDI-TOF mass spectrometry in the clinical microbiology laboratory[J]. Clinical Microbiology Newsletter,2011,33(12): 87-93. |
[2] | FENSELAU C,DEMIREV PA.Characterization of intact microorganisms by MALDI mass spectrometry[J]. Mass Spectrom Rev,2001,20(4): 157-171. |
[3] | FERREIRA L,SÁNCHEZ-JUANES F,GONZÁLEZ-ÁVILA M,et al. Direct identification of urinary tract pathogens from urine samples by matrix-assisted laser desorption ionization-time of flight mass spectrometry[J]. J Clin Microbiol, 2010,48(6): 2110-2115. |
[4] | SENG P,DRANCOURT M,GOURIET F,et al.Ongoing revolution in bacteriology: routine identification of bacteria by matrix-assisted laser desorption ionization time-of-flight mass spectrometry[J]. Clin Infect Dis,2009,49(4): 543-551. |
[5] | VAN VEEN SQ,CLAAS EC,KUIJPER EJ.High-throughput identification of bacteria and yeast by matrix-assisted laser desorption ionization-time of flight mass spectrometry in conventional medical microbiology laboratories[J]. J Clin Microbiol, 2010,48(3): 900-907. |
[6] | DUBOIS D, LEYSSENE D, CHACORNAC JP, et al.Identification of a variety of Staphylococcus species by matrix-assisted laser desorption ionization-time of flight mass spectrometry[J]. J Clin Microbiol, 2010, 48(3): 941-945. |
[7] | BRANDA JA, MARKHAM RP, GARNER CD, et al.Performance of the Vitek MS v2. 0 system in distinguishing Streptococcus pneumoniae from nonpneumococcal species of the Streptococcus mitis group[J]. J Clin Microbiol, 2013, 51(9): 3079-3082. |
[8] | HE Y, LI H, LU X, et al.Mass spectrometry biotyper system identifies enteric bacterial pathogens directly from colonies grown on selective stool culture media[J]. J Clin Microbiol, 2010, 48(11): 3888-3892. |
[9] | DEGAND N,CARBONNELLE E,DAUPHIN B,et al.Matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of nonfermenting gram-negative bacilli isolated from cystic fibrosis patients[J]. J Clin Microbiol, 2008, 46(10): 3361-3367. |
[10] | MELLMANN A,BIMET F,BIZET C,et al.High interlaboratory reproducibility of matrix-assisted laser desorption ionization-time of flight mass spectrometry-based species identification of nonfermenting bacteria[J]. J Clin Microbiol, 2009, 47(11): 3732-3734. |
[11] | NIITSUMA K,SAITO M,KOSHIBA S,et al.Identi-fication of Mycobacteria by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry-using reference strains and clinical isolates of Mycobacterium[J]. Kekkaku, 2014, 89(5): 555-563. |
[12] | 周昭彦,胡必杰,鲍容,等.MALDI-TOF质谱快速鉴定非结核分枝杆菌方法的建立和评价[J].中华检验医学杂志,2013,36(7):610-614. |
[13] | NAGY E,MAIER T,URBAN E,et al.Species identi-fication of clinical isolates of Bacteroides by matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry[J]. Clin Microbiol Infect,2009,15(8): 796-802. |
[14] | XIAO D,TAO XX,WANG P,et al.Rapid and high-throughput identification of recombinant bacteria with mass spectrometry assay[J]. Biomed Environ Sci, 2014, 27(4): 250-258. |
[15] | MARKLEIN G,JOSTEN M,KLANKE U,et al.Matrix-assisted laser desorption ionization-time of flight mass spectrometry for fast and reliable identification of clinical yeast isolates[J]. J Clin Microbiol, 2009,47(9): 2912-2917. |
[16] | STEVENSON LG,DRAKE SK,SHEA YR,et al.Evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of clinically important yeast species[J]. J Clin Microbiol, 2010,48(10): 3482-3486. |
[17] | ZHANG L,XIAO M,WANG H,et al.Yeast identi-fication algorithm based on use of the Vitek MS system selectively supplemented with ribosomal DNA sequencing: proposal of a reference assay for invasive fungal surveillance programs in China[J]. J Clin Microbiol, 2014,52(2): 572-577. |
[18] | LA SCOLA B,RAOULT D.Direct identification of bacteria in positive blood culture bottles by matrix-assisted laser desorption ionisation time-of-flight mass spectrometry[J]. PLoS One,2009,4(11): e8041. |
[19] | PROD'HOM G,BIZZINI A,DURUSSEL C,et al. Matrix-assisted laser desorption ionization-time of flight mass spectrometry for direct bacterial identification from positive blood culture pellets[J]. J Clin Microbiol, 2010,48(4): 1481-1483. |
[20] | DRANCOURT M.Detection of microorganisms in blood specimens using matrix-assisted laser desorption ionization time-of-flight mass spectrometry: a review[J]. Clin Microbiol Infect,2010,16(11): 1620-1625. |
[21] | MAJCHERCZYK PA,MCKENNA T,MOREILLON P, et al.The discriminatory power of MALDI-TOF mass spectrometry to differentiate between isogenic teicoplanin-susceptible and teicoplanin-resistant strains of methicillin-resistant Staphylococcus aureus[J]. FEMS Microbiol Lett, 2006,255(2): 233-239. |
[22] | DU Z, YANG R, GUO Z,et al.Identification of Staphylococcus aureus and determination of its methicillin resistance by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry[J]. Anal Chem, 2002,74(21): 5487-5491. |
[23] | CAMARA JE,HAYS FA.Discrimination between wild-type and ampicillin-resistant Escherichia coli by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry[J]. Anal Bioanal Chem,2007,389(5): 1633-1638. |
[24] | BURCKHARDT I,ZIMMERMANN S.Using matrix-assisted laser desorption ionization-time of flight mass spectrometry to detect carbapenem resistance within 1 to 2.5 hours[J]. J Clin Microbiol, 2011,49(9): 3321-3324. |
[25] | MARINACH C,ALANIO A,PALOUS M,et al.MALDI-TOF MS-based drug susceptibility testing of pathogens: the example of Candida albicans and fluconazole[J]. Proteomics,2009,9(20): 4627-4631. |
[26] | WOLTERS M,ROHDE H,MAIER T,et al.MALDI-TOF MS fingerprinting allows for discrimination of major methicillin-resistant Staphylococcus aureus lineages[J]. Int J Med Microbiol,2011,301(1): 64-68. |
[27] | GRIFFIN PM,PRICE GR,SCHOONEVELDT JM,et al.Use of matrix-assisted laser desorption ionization-time of flight mass spectrometry to identify vancomycin-resistant enterococci and investigate the epidemiology of an outbreak[J]. J Clin Microbiol, 2012,50(9): 2918-2931. |
[28] | BITTAR F,OUCHENANE Z,SMATI F,et al.MALDI-TOF-MS for rapid detection of staphylococcal Panton-Valentine leukocidin[J]. Int J Antimicrob Agents,2009,34(5): 467-470. |
[29] | LU JJ,TSAI FJ,HO CM,et al.Peptide biomarker discovery for identification of methicillin-resistant and vancomycin-intermediate Staphylococcus aureus strains by MALDI-TOF[J]. Anal Chem, 2012,84(13): 5685-5692. |
[1] | MIAO Xingguo, YE Hui, SU Feifei. Relationship between GeneXpert MTB/RIF assay determination load and Mycobacterium tuberculosis culture and phenotype of rifampicin resistance [J]. Laboratory Medicine, 2023, 38(9): 874-877. |
[2] | YANG Xue, ZHU Jun, JIANG Lingli, WANG Qing, HU Xiaobo. Evaluation on the consistency of blind sample test results of 9 SARS-CoV-2 nucleic acid determination kits in Shanghai,China [J]. Laboratory Medicine, 2023, 38(8): 776-780. |
[3] | SUN Zepeng, WANG Hongbin, WANG Jiandong, SONG Dewei, XIAO Peng. Analysis and progress of peptide and protein biomarker methodology for myocardial injury [J]. Laboratory Medicine, 2023, 38(8): 784-789. |
[4] | TAN Chunyan, ZHOU Ying, MO Zhijiang. Errors in Appendix B examples of WS/T 505—2017 and correction [J]. Laboratory Medicine, 2023, 38(6): 569-573. |
[5] | ZENG Yanfen, WU Quanming, ZHOU Huan, ZHANG Qiuqin, KANG Yanli, LI Yao, CHEN Xijun, HUANG Jiangang, CHEN Falin. Determination limits of a severe acute respiratory syndrome coronavirus 2 nucleic acid determination reagent in 4 determination systems [J]. Laboratory Medicine, 2023, 38(3): 261-266. |
[6] | LU Qiyuan, LU Jianhua. Biomarker research progress for the diagnosis of periprosthetic joint infection [J]. Laboratory Medicine, 2023, 38(10): 997-1002. |
[7] | WEI Rui, YUAN Xu, TIAN Xuewen, LU Yanjun. Clinical and laboratory characteristics of human metapneumovirus infection children in a Grade A Class 3 hospital in Wuhan [J]. Laboratory Medicine, 2023, 38(1): 18-22. |
[8] | YANG Danping, WANG Hong, WANG Can, CHEN Wei, YANG Aiping. Diagnostic efficacy and clinical application evaluation of SARS-CoV-2 antigen determination [J]. Laboratory Medicine, 2023, 38(1): 28-31. |
[9] | WANG Shiqi, LI Henan, LIU Jingbo, WANG Zhanwei, WANG Zhiren, CHI Dali, WANG Hui. Application evaluation of loop-mediated isothermal amplification in determining Clostridioides difficile in fecal samples [J]. Laboratory Medicine, 2022, 37(9): 860-863. |
[10] | CHEN Qian, SHAN Zhiming, SONG Chao, KANG Fengfeng, JIN Jing, LI Weixing. Status of quality management of new laboratories for nucleic acid determination of SARS-CoV-2 in Zhejiang [J]. Laboratory Medicine, 2022, 37(7): 669-673. |
[11] | ZHU Yuqing, WANG Haibin, WANG Lianming, ZHAO Fang, FENG Pinning, ZHANG Peng, GUO Shuren, PENG Yibing, CHENG Liming, CHUAN Liangmin, WANG Hualiang. A multi-center evaluation of a domestic glutathione reductase determination kit [J]. Laboratory Medicine, 2022, 37(5): 449-455. |
[12] | OU Tong, ZHANG Bing, ZHANG Xiuming. Re-understanding about the rational application of clinical laboratory determination technologies for COVID-19 diagnosis [J]. Laboratory Medicine, 2022, 37(4): 303-308. |
[13] | YANG Xue, JU Yi, OU Yuanzhu, ZHU Yuqing, XU Chong, JIANG Lingli, WANG Qing, ZHOU Jing. Analysis on the results of external quality assessment of mutual recognition quantitative items in Shanghai [J]. Laboratory Medicine, 2022, 37(12): 1129-1134. |
[14] | ZHANG Chen, LI Ting, MENG Qinghao, XIE Nan, ZHANG Weimin, ZHAO Fei, LI Min, GAO Xuan, YANG Sijie. Performance evaluation of glycerol as stabilizer for the preparation of seminal plasma biochemical quality control products [J]. Laboratory Medicine, 2022, 37(12): 1200-1203. |
[15] | LIU Congcong, LI Jiaping, ZHOU Hongwei. Performance evaluation of 2 mass spectrometry systems in clinical microbial identification [J]. Laboratory Medicine, 2022, 37(11): 1084-1088. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||