Laboratory Medicine ›› 2024, Vol. 39 ›› Issue (7): 709-714.DOI: 10.3969/j.issn.1673-8640.2024.07.016
Previous Articles Next Articles
ZHAO Chunhe1, SHAO Huihui1, CUI Weiqi1, XIA Wei2, QU Linlin1()
Received:
2023-08-20
Revised:
2024-02-26
Online:
2024-07-30
Published:
2024-07-31
CLC Number:
ZHAO Chunhe, SHAO Huihui, CUI Weiqi, XIA Wei, QU Linlin. Progress in application of blood coagulation point-of-care testing[J]. Laboratory Medicine, 2024, 39(7): 709-714.
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.shjyyx.com/EN/10.3969/j.issn.1673-8640.2024.07.016
[1] | 胡会利, 李宁. 电化学测量[M]. 北京: 化学工业出版社, 2020. |
[2] | 肖立琼, 王雷, 杨婷, 等. 心脏手术体外循环中使用i-STAT-Kaolin ACT和Medtronic ACT Ⅱ测量活化凝血时间的比较研究[J]. 国际检验医学杂志, 2020, 41(15):1831-1834. |
[3] |
KIM S J, LEE E Y, PARK R, et al. Comparison of prothrombin time derived from CoaguChek XS and laboratory test according to fibrinogen level[J]. J Clin Lab Anal, 2015, 29(1):28-31.
DOI PMID |
[4] | Corrigendum to CoaguChek® XS versus standard laboratory prothrombin time for anticoagulant monitoring in patients with antiphospholipid syndrome[J]. Lupus, 2022, 31(5):565-574. |
[5] | 张明光, 宁力清. CoaguChek XS检测仪在下肢深静脉血栓形成疾病中的应用[J]. 中医临床研究, 2017, 9(12):16-17. |
[6] | SHADLYN T, BAUMAN M, TANDON P, et al. Accuracy and precision of point-of-care international normalized ratio in patients with liver disease[J]. J Pediatr Gastroenterol Nutr, 2023, 76(6):704-709. |
[7] | MOIZ B, RASHID A, HASAN M, et al. Prospective comparison of point-of-care device and standard analyzer for monitoring of international normalized ratio in outpatient oral anticoagulant clinic[J]. Clin Appl Thromb Hemost, 2018, 24(7):1153-1158. |
[8] | KIM Y S, CHOI J W, SONG S H, et al. Comparison of the international normalized ratio between a point-of-care test and a conventional laboratory test:the latter performs better in assessing warfarin-induced changes in coagulation factors[J]. Ann Lab Med, 2023, 43(4):337-344. |
[9] | 王桢昌, 司士辉, 陈金华, 等. 双幅正弦波激励频移法的压电石英传感器用于测定凝血时间[J]. 传感器世界, 2023, 29(2):19-25. |
[10] | CHEN J Y, PENN L S, XI J. Quartz crystal microbalance:sensing cell-substrate adhesion and beyond[J]. Biosens Bioelectron, 2018, 99:593-602. |
[11] | MA Y, XIAO X, JI Q. Design of surface nanostructures for chirality sensing based on quartz crystal microbalance[J]. Beilstein J Nanotechnol, 2022, 13:1201-1219. |
[12] | LIM H J, SAHA T, TEY B T, et al. Quartz crystal microbalance-based biosensors as rapid diagnostic devices for infectious diseases[J]. Biosens Bioelectron, 2020, 168:112513. |
[13] | 潘泓州. 基于QCM的凝血检测系统设计与实现[D]. 成都: 电子科技大学, 2022. |
[14] | 潘存泽. 基于QCM检测的软件系统设计与实现[D]. 成都: 电子科技大学, 2021. |
[15] |
BAYRAMOGLU G, OZALP C, OZTEKIN M, et al. Design of an aptamer-based magnetic adsorbent and biosensor systems for selective and sensitive separation and detection of thrombin[J]. Talanta, 2019, 191:59-66.
DOI PMID |
[16] | 盛天宇. 基于电化学阻抗法的凝血检测仪研制[D]. 南京: 东南大学, 2021. |
[17] | VRANKEN N P A, THEELEN A J A J, ORBONS T, et al. Point-of-care measurement of kaolin activated clotting time during cardiopulmonary bypass:a single sample comparison between ACT plus and i-STAT[J]. J Extra Corpor Technol, 2021, 53(1):57-61. |
[18] | SCHOBER P, BOSSERS S M, KOOLWIJK J, et al. Prehospital coagulation measurement by a portable blood analyzer in a helicopter emergency medical service(HEMS)[J]. Am J Emerg Med, 2021, 46:137-140. |
[19] | HARTMANN J, MURPHY M, DIAS J D. Viscoelastic hemostatic assays:moving from the laboratory to the site of care-a review of established and emerging technologies[J]. Diagnostics(Basel), 2020, 10(2):118. |
[20] | ICHIKAWA Y, KAWANO K, MORI M, et al. Sonoclot's usefulness in prediction of cardiopulmonary arrest prognosis:a proof of concept study[J]. Open Med(Wars), 2022, 17(1):414-422. |
[21] | 万鹏, 童华生, 张兴钦, 等. Sonoclot 分析仪在重症中暑并发弥散性血管内凝血中的诊断价值[J]. 实用医学杂志, 2014(16):2562-2565. |
[22] | ZHANG Z L, CHEN Y P, TAO C H, et al. Establishment of reference intervals and transfusion criterion for sonoclot analysis[J]. J Huazhong Univ Sci Technolog Med Sci, 2016, 36(4):614-617. |
[23] | SACKMANN E K, FULTON A L, BEEBE D J. The present and future role of microfluidics in biomedical research[J]. Nature, 2014, 507(7491):181-189. |
[24] | NEEVES K B, ONASOGA A A, WUFSUS A R. The use of microfluidics in hemostasis:clinical diagnostics and biomimetic models of vascular injury[J]. Curr Opin Hematol, 2013, 20(5):417-423. |
[25] | 张思祥, 竭霞, 胡雪迎, 等. 微流控电阻抗检测系统构建及其应用[J]. 分析科学学报, 2020, 36(2):295-298. |
[26] |
GUAN Y, ZHANG K, XU F, et al. An integrated platform for fibrinogen quantification on a microfluidic paper-based analytical device[J]. Lab Chip, 2020, 20(15):2724-2734.
DOI PMID |
[27] | 李恬怡. 基于导电弹性体材料的血液凝固检测微流控芯片[D]. 北京: 北京化工大学, 2023. |
[28] | 杨志华, 罗娜, 王长奇, 等. POCT凝血分析仪电化学法检测的临床应用[J]. 实验与检验医学, 2016, 34(5):635-638. |
[29] | 郑安然, 张威, 郭振, 等. 活化部分凝血活酶时间检测石墨烯传感器的研制[J]. 光学精密工程, 2019, 27(6):1387-1396. |
[30] | 屈玲. 压电石英晶体凝血传感器检测血浆纤维蛋白原和凝血因子Ⅷ的实验研究[D]. 重庆: 第三军医大学, 2004. |
[31] | VALET C, MAGNEN M, QIU L, et al. Sepsis promotes splenic production of a protective platelet pool with high CD40 ligand expression[J]. J Clin Invest, 2022, 132(7):e153920. |
[32] | 贾媛, 白世茹, 李如意, 等. 血小板功能检测的常用方法及容易忽略的影响因素[J]. 中国心血管杂志, 2020, 25(2):197-200. |
[33] | KOLTAI K, KESMARKY G, FEHER G, et al. Platelet aggregometry testing:molecular mechanisms,techniques and clinical implications[J]. Int J Mol Sci, 2017, 18(8):1803. |
[34] | FRANCHINI M. The platelet function analyzer(PFA-100):an update on its clinical use[J]. Clin Lab, 2005, 51(7-8):367-372. |
[35] | 中华医学会心血管病学分会, 中华心血管病杂志编辑委员会. 抗血小板药物治疗反应多样性临床检测和处理的中国专家建议[J]. 中华心血管病杂志, 2014, 42(12):986-991. |
[36] | LARDINOIS B, HARDY M, MICHAUX I, et al. Monitoring of unfractionated heparin therapy in the intensive care unit using a point-of-care aPTT:a comparative,longitudinal observational study with laboratory-based aPTT and anti-Xa activity measurement[J]. J Clin Med, 2022, 11(5):1338. |
[37] | MILLING T J Jr, ZIEBELL C M. A review of oral anticoagulants,old and new,in major bleeding and the need for urgent surgery[J]. Trends Cardiovasc Med, 2020, 30(2):86-90. |
[38] |
RIZOS T, HERWEH C, JENETZKY E, et al. Point-of-care international normalized ratio testing accelerates thrombolysis in patients with acute ischemic stroke using oral anticoagulants[J]. Stroke, 2009, 40(11):3547-3551.
DOI PMID |
[39] | 林忠秋, 张宏亮, 丘岳, 等. 新型口服抗凝药在冠状动脉粥样硬化性心脏病中的应用研究进展[J]. 广西医学, 2022, 44(16):1920-1924. |
[40] | PADAYATTIL JOSE S, BANZATO A, CARRARO P, et al. Point of care testing(POCT) to assess drug concentration in patients treated with non-vitamin K antagonist oral anticoagulants(NOACs)[J]. Thromb Res, 2018, 163:100-104. |
[41] | HÄRTIG F, BIRSCHMANN I, PETER A, et al. Point-of-care testing of coagulation in patients treated with edoxaban[J]. J Thromb Thrombolysis, 2020, 50(3):632-639. |
[42] | 曹辉, 吴俊. 血凝学即时检验的临床应用[J]. 中华检验医学杂志, 2020, 43(8):837-841. |
[1] | ZHOU Jian, REN Xuemei, WANG Xin, LI Zhuo. Research progress and challenges on CRISPR/Cas nucleic acid diagnosis system [J]. Laboratory Medicine, 2024, 39(6): 608-614. |
[2] | SUN Zepeng, WANG Hongbin, WANG Jiandong, SONG Dewei, XIAO Peng. Analysis and progress of peptide and protein biomarker methodology for myocardial injury [J]. Laboratory Medicine, 2023, 38(8): 784-789. |
[3] | LIU Lu, WANG Li, LI Kexin, CUI Wei. Development and application of intelligent blood collection management system [J]. Laboratory Medicine, 2023, 38(4): 373-377. |
[4] | LU Qiyuan, LU Jianhua. Biomarker research progress for the diagnosis of periprosthetic joint infection [J]. Laboratory Medicine, 2023, 38(10): 997-1002. |
[5] | YUE Caidie, LI Junyan, DING Aijun, XIE Li, ZENG Weikun. Research progress of rapid determination methods for SARS-CoV-2 antigen [J]. Laboratory Medicine, 2023, 38(1): 87-93. |
[6] | LI Daming, LÜ Xing, JIANG Chuanhao, HU Min. Clinical application of gene chip technology for determining respiratory pathogens rapialy in pulmonary infection patients after renal transplantation [J]. Laboratory Medicine, 2022, 37(9): 864-867. |
[7] | LIU Hongqian, SONG Chaohui, LIANG Qiaomi. Establishment and clinical application of multiple RT-PCR MassARRAY for the determinations of 27 respiratory pathogens [J]. Laboratory Medicine, 2021, 36(9): 939-946. |
[8] | TANG Jun, CAO Hongmei. Establishment of influenza A H1N1 virus RNA determination method and its clinical application [J]. Laboratory Medicine, 2021, 36(7): 738-742. |
[9] | GE Danhong, TANG Liping, OU Yuanzhu, YU Xiaoxuan, LIU Wenbin, LIN Feiran, GONG Jingkai, ZHU Yuqing. Assessment of internal quality control plan for microfluidic chip POCT [J]. Laboratory Medicine, 2021, 36(6): 674-678. |
[10] | ZHAO Ran, LIU Wenbin, LIN Feiran, GONG Jingkai, YU Xiaoxuan, GE Danhong, TANG Liping, OU Yuanzhu. Internal quality control and evaluation of blood gas analysis based on Westgard sigma rules [J]. Laboratory Medicine, 2021, 36(5): 544-548. |
[11] | YUAN Muge, WU Wenjian, HU Zhaohui, CHEN Jiachang, YU Shihui, OU Xiaohua, MAO Linlin, WU Haiyan. Germline mutation detection in early-stage breast cancer by next-generation sequencing [J]. Laboratory Medicine, 2021, 36(3): 325-329. |
[12] | ZOU Jihua, ZHANG Wei, SHEN Min, ZHANG Man, TU Minmin, WANG Huimin, ZHOU Houqing. Research progress in the separation of serum lipoprotein subfractions and lipoprotein(a) [J]. Laboratory Medicine, 2021, 36(10): 1078-1086. |
[13] | ZHANG Qiu, LI Jie, WANG Meng, WANG Yi, YANG Bo, HU Zheng. Development of colloidal gold immunochromatography assay for the rapid detection of Legionella pneumophila [J]. Laboratory Medicine, 2020, 35(7): 726-733. |
[14] | NIU Jing, QUAN Wenqiang, LI Dong. Establishment and application of loop-mediated isothermal amplification for EGFR gene L858R mutation determination in non-small cell lung cancer patients [J]. Laboratory Medicine, 2020, 35(3): 273-277. |
[15] | FU Xiaorui, KANG Beipei, XU Xiuli, ZHAO Feng, ZHANG Pengliang, ZHOU Lei. Clinical application of rapid pathogen detection technologies for detecting influenza A virus [J]. Laboratory Medicine, 2020, 35(11): 1165-1168. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||