Establishment and performance evaluation of candidate reference measurement procedure for the determination of immunosuppressive drugs in human whole blood by ID-LC-MS/MS

YANG Xiaodong1, LI Quanle1, PAN Qingqing1, ZHOU Jing1, XIE Yangmin1, ZOU Jihua1(), SHEN Min1(), ZHANG Man2   

  1. 1. Reference Laboratory,MedicalSystem Biotechnology Co.,Ltd.,Ningbo 315104,Zhejiang,China
    2. Department of Clinical Laboratory,Beijing Shijitan Hospital,Capital Medical University,Beijing 100038,China
  • Received:2022-01-18 Revised:2022-12-07 Online:2023-03-28 Published:2023-05-24
  • Contact: ZOU Jihua,SHEN Min

Abstract:

Objective To establish a candidate reference measurement procedure for immunosuppressive drugs(tacrolimus,sirolimus,everolimus and cyclosporine A) in human whole blood by isotope-dilution liquid chromatography-tandem mass spectrometry(ID-LC-MS/MS),and to evaluate its analytical performance. Methods Human whole blood samples were prepared by a simple protein precipitation method,and ID-LC-MS/MS was used to determine tacrolimus,sirolimus,everolimus and cyclosporine A quantitatively. The performance,including linearity,limit of quantitation,relative matrix effect,precision and trueness,were evaluated. Results ID-LC-MS/MS allowed the determination of the 4 immunosuppressive drugs within a total runtime of 4.5 min. ID-LC-MS/MS allowed the determination of cyclosporine A in the range of 10-500 ng/mL. Tacrolimus,sirolimus and everolimus were analyzed in the range of 1-50 ng/mL. The limit of quantitation was 10 ng/mL for cyclosporine A and 1 ng/mL for the others. The relative matrix effects were ≤8.64%. The precisions for intra-day and inter-day coefficients of variation(CV) were ≤5%. The average recovery rates were found to be 98.84%-100.99% for the 4 immunosuppressive drugs. Expanded measurement uncertainties were found to be ≤7.91 % for tacrolimus(k=2),≤7.97 % for sirolimus(k=2),≤7.14 % for everolimus(k=2) and ≤7.91 % for cyclosporine A(k=2). Conclusions The candidate reference measurement procedure for tacrolimus,sirolimus,everolimus and cyclosporine A in human whole blood by ID-LC-MS/MS has been established successfully,which can be used in value traceability and standardization.

Key words: Immunosuppressive drug, Isotope-dilution liquid chromatography-tandem mass spectrometry, Reference measurement procedure, Performance evaluation