检验医学 ›› 2018, Vol. 33 ›› Issue (12): 1103-1107.DOI: 10.3969/j.issn.1673-8640.2018.12.010

• 临床应用研究·论著 • 上一篇    下一篇

溶血对液相色谱串联质谱检测血浆中儿茶酚胺及其代谢产物的影响

袁凤喜1, 薛雄燕2, 陈彩凤1, 赖月红1, 梁泳仪1, 李岩3, 谢雯春3, 杨绍杰1, 吴燕杰1   

  • 收稿日期:2018-02-07 出版日期:2018-12-26 发布日期:2018-12-27
  • 作者简介:null

    作者简介:袁凤喜,女,1991年生,技士,主要从事临床生化检验工作。

Influence of hemolysis on the results of plasma catecholamines and their metabolites by liquid chromatography-tandem mass spectrometry

YUAN Fengxi1, XUE Xiongyan2, CHEN Caifeng1, LAI Yuehong1, LIANG Yongyi1, LI Yan3, XIE Wenchun3, YANG Shaojie1, WU Yanjie1   

  1. 1. Shunde Clinlab-Link Medical Laboratory,Guangdong Bio-healtech Advanced Company Limited,Foshan 528000,Guangdong,China
    2. Department of Clinical Laboratory,the First People's Hospital of Foshan,Foshan 528000,Guangdong,China
    3. Institute of Biophysics,Chinese Academy of Science,Beijing 100101,China
  • Received:2018-02-07 Online:2018-12-26 Published:2018-12-27

摘要:

目的 探讨溶血对液相色谱串联质谱(LC-MS/MS)检测血浆儿茶酚胺[肾上腺素(E)、去甲肾上腺素(NE)、多巴胺(DA)]及其代谢产物[变肾上腺素(MN)、去甲变肾上腺素(NMN)、3-甲氧基酪胺(3-MT)]的影响。方法 在正常血浆样本和轻度溶血[血红蛋白(Hb)为0.75 g/L]、中度溶血(Hb分别为1.50、3.00 g/L)、重度溶血(Hb为7.50 g/L)样本中分别加入儿茶酚胺及其代谢产物的标准品溶液,制成低值和高值样本。将上述样本采用弱阳离子固相萃取板进行前处理,每份样本重复检测3次。采用LC-MS/MS检测前处理提取液中的儿茶酚胺及其代谢产物的水平。结果 无论MN、NMN、3-MT是高值还是低值,除3-MT在重度溶血(Hb为7.50 g/L)时未能被检测到外,其他不同溶血程度样本MN、NMN、3-MT检测结果与正常样本比较,差异均无统计学意义(P>0.05)。高值3-MT、MN、NMN 3次检测结果的变异系数(CV)均<15%。低值3-MT在中度溶血(Hb为1.50 g/L)时、低值NMN在重度溶血(Hb为7.50 g/L)时,3次检测结果CV均>15%。对于Hb为3.00 g/L的中度溶血样本,无论DA、E、NE是高值还是低值均无法检出;当Hb≤1.50 g/L时,E、NE和DA低值样本的检测结果与正常样本比较,差异无统计学意义(P>0.05);DA和NE高值样本的检测结果与正常样本比较,差异无统计学意义(P>0.05);而E高值样本的检测结果在轻度溶血(Hb为1.5 g/L)时明显降低(P<0.05)。高、低值DA、E、NE在Hb≤1.50 g/L时3次检测结果的CV均<15%。结论 中、重度溶血对LC-MS/MS检测儿茶酚胺及其代谢产物有不同程度的影响。

关键词: 儿茶酚胺, 代谢产物, 溶血, 血红蛋白, 液相色谱串联质谱

Abstract:

Objective To study the influence of hemolysis on the results of plasma catecholamines [epinephrine(E),norepinephrine(NE) and dopamine(DA)] and their metabolites [metanephrine(MN),normetanephrine(NMN) and 3-methoxytyramine(3-MT)] by liquid chromatography-tandem mass spectrometry (LC-MS/MS).Methods The standard solutions of catecholamines and their metabolites were added to normal plasma and plasma with different degrees of hemolysis [the levels of hemoglobin(Hb) were 0.75 g/L(mild hemolysis),1.50 and 3.00 g/L(moderate hemolysis) and 7.50 g/L(severe hemolysis) to make the samples with low and high levels of catecholamines and their metabolites. All the samples were subjected to weak cation-exchange solid phase extraction with 3 replicates. The catecholamines and their metabolites in extraction solutions were analyzed by LC-MS/MS.Results No matter the levels of MN,NMN,3-MT were high or low,the levels of MN,NMN and 3-MT had no statistical significance among normal samples and all hemolytic samples(P>0.05),except the signal of 3-MT could not be determined in severely hemolytic samples(the level of Hb was 7.50 g/L). The coefficients of variation(CV) of MN,NMN and 3-MT in high-level samples from 3 replicates were <15%. When the levels of Hb were 1.50 g/L for low-level 3-MT and 7.50 g/L for low-level NMN,the CV were >15%. When the level of Hb was 3.00 g/L,DA,E and NE were not determined in low-level or high-level samples. When the level of Hb was ≤1.50 g/L,the results of E,NE and DA in low-level samples and the results of DA and NE in high-level samples had no statistical significance among normal samples and hemolytic samples(P>0.05),but the result of E in high-level samples decreased,when the level of Hb was 1.50 g/L(P<0.05). The CV of E,NE and DA in low-level and high-level samples were all <15%,when the level of Hb was ≤1.50 g/L.Conclusions Moderate and severe hemolysis has influence on the results of catecholamines and their metabolites by LC-MS/MS.

Key words: Catecholamine, Metabolite, Hemolysis, Hemoglobin, Liquid chromatography-tandem mass spectrometry