检验医学 ›› 2014, Vol. 29 ›› Issue (2): 148-152.DOI: 10.3969/j.issn.1673-8640.2014.02.014

• 技术研究与评价·论著 • 上一篇    下一篇

化学沉淀法测定小而密低密度脂蛋白方法的建立

于群1, 王惠民1, 季伙燕1, 苏建友1, 丛辉1, 顾国浩2, 沈国荣3   

  1. 1. 南通大学附属医院检验医学中心, 江苏 南通 226001;
    2. 苏州大学附属第一医院检验科, 江苏 苏州 215006; 3. 南通大学附属吴江医院检验科, 江苏 吴江 215200
  • 收稿日期:2013-04-29 出版日期:2014-02-20 发布日期:2014-02-20
  • 通讯作者: 王惠民, 联系电话:0513-85052102
  • 作者简介:于 群, 女, 1987年生, 学士, 主要研究方向为脂蛋白分离技术。
  • 基金资助:

    江苏省“科教兴卫”医学重点学科建设资助项目(XK200723);江苏省南通市社会发展项目(S2009012)

Establishment on chemistry precipitation assay for the determination of small dense low-density lipoprotein

YU Qun1, WANG Huimin1, JI Huoyan1, SU Jianyou1, CONG Hui1, GU Guohao2, SHEN Guorong3.   

  1. 1. Laboratory Medicine Center, the Affiliated Hospital of Nantong University, Jiangsu Nantong 226001, China; 2. Department of Clinical Laboratory, the First Affiliated Hospital of Soochow University, Jiangsu Soochow 215006, China; 3. Department of Clinical Laboratory, Wujiang Hospital, Nantong University, Jiangsu Wujiang 215200, China
  • Received:2013-04-29 Online:2014-02-20 Published:2014-02-20

摘要:

目的 利用化学沉淀原理建立小而密低密度脂蛋白(sdLDL)快速、简便的检测方法。方法 通过比较不同种类及不同浓度沉淀剂对血清样本中脂蛋白的分离效果, 确定最终沉淀剂, 并对化学沉淀法测定血清sdLDL-C的精密度、线性范围和回收率进行分析。结果 最终选择140 U/mL肝素-90 mmol/L Mg2+作为沉淀剂测定血清sdLDL 胆固醇(sdLDL-C)含量。化学沉淀法测定sdLDL-C在0.14~1.44 mmol/L范围内线性关系良好, 回归方程为Y=1.025X-0.197, r=0.988;对高、低2组不同sdLDL-C浓度的样本批内变异系数(CV)分别为2.83%、3.19%, 批间CV分别为5.49%、6.13%;回收率为83.81%。结论 sdLDL化学沉淀法具有样本用量少、操作简便、成本低廉等优点, 更适合常规实验室检测血清sdLDL-C含量。

关键词: 小而密低密度脂蛋白, 沉淀法, 化学法

Abstract:

Objective To establish a simple and rapid method for the determination of small dense low-density lipoprotein(sdLDL) by utilizing the principle of precipitation. Methods The final and most appropriate precipitation reagents were identified through comparing the separation effect of different types and different concentrations of precipitation reagents for separating serum lipoproteins. The precision, linear range and recovery rate of chemistry precipitation assay were also analyzed. Results Finally, 140 U/mL of heparin and 90 mmol/L of Mg2+ as the precipitation reagents were used to determine the concentrations of serum sdLDL cholesterol(sdLDL-C). The chemistry precipitation assay was linear at 0.14-1.44 mmol/L sdLDL-C, and the regression equation was Y=1.025X-0.197, r=0.988. The within-run coefficients of variation(CV) of high and low sdLDL-C concentration specimens were 2.83% and 3.19%, respectively, and the between-run CV were 5.49% and 6.13%. The recovery rate was 83.81%. Conclusions The chemistry precipitation assay for the determination of sdLDL has the advantages of less serum consumption, simple operation, low cost and so on. It is more suitable for clinical laboratory to determine serum sdLDL-C.

Key words: Small dense low-density lipoprotein, Precipitation assay, Chemical method

中图分类号: