检验医学 ›› 2013, Vol. 28 ›› Issue (9): 824-827.DOI: 10.3969/j.issn.1673-8640.2013.09.022

• 技术研究与评价.论著 • 上一篇    下一篇

聚乙二醇沉淀法与凝胶色谱层析法检测巨泌乳素的相关性研究

王霞1,刘金玲2,高硕2   

  1. 1.天津市血液中心,天津 300110;
    2.天津市医科大学总医院,天津 300052
  • 收稿日期:2012-09-21 修回日期:2013-09-25 出版日期:2013-09-15 发布日期:2013-09-25
  • 作者简介:王 霞,女,1977年生,硕士,主管技师,主要从事临床检验诊断工作。

Study on the correlation between polyethylene glycol precipitation treatment and gel filtration chromatography in the detection of macroprolactin

WANG Xia1, LIU Jinling2,GAO Shuo2   

  1. 1.Tianjin Blood Center, Tianjin 300110, China;
    2.General Hospital,Tianjin Medical University,Tianjin 300052,China
  • Received:2012-09-21 Revised:2013-09-25 Online:2013-09-15 Published:2013-09-25

摘要:

目的 探讨聚乙二醇(PEG)沉淀法检测巨泌乳素(MPRL)方法的可行性。方法 将26例高泌乳素血症(HPRL)患者按临床表现和影像学资料分为真性HPRL组(简称真泌组)11例及MPRL血症组(简称巨泌组)15例。采用凝胶色谱层析(GFC)法分离泌乳素(PRL)各组分,检测各组分PRL浓度,同时将所有标本进行PEG沉淀,检测处理后单体PRL浓度,并与GFC法单体PRL检测结果进行相关性分析。结果 巨泌组与真泌组的PRL层析谱不同,真泌组以单体PRL为主,而巨泌组以巨PRL为主。真泌组与巨泌组血清处理前总PRL浓度差异无统计学意义(P>0.05),而处理后真泌组明显高于巨泌组(P<0.05)。PEG沉淀法与GFC法检测真泌组与巨泌组单体PRL浓度差异无统计学意义(P>0.05),且相关性良好[相关系数(r)=0.844,P<0.05]。结论 PEG沉淀法检测MPRL结果与GFC法有良好的相关性,且经济、简便、易行,可作为临床常规筛查方法。

关键词: 泌乳素, 巨泌乳素, 高泌乳素血症, 聚乙二醇, 凝胶色谱层析法

Abstract:

Objective To investigate the feasibility of polyethylene glycol(PEG)precipitation treatment in the detection of macroprolactine(MPRL). Methods A total of 26 hyperprolactinemia (HPRL) patients were classified into 2 groups: genuine HPRL group (11 cases) and macroprolactinemia group (15 cases) according to the clinical and imaging data. By gel filtration chromatography (GFC), the components of prolactin (PRL) were separated, and their levels were determined. After PEG precipitation treatment, the concentration of monomer PRL was determined, the results were compared with those by GFC, and the correlation was analyzed. Results The chromatogram of macroprolactinemia group was different from that of genuine HPRL group. The genuine HPRL group was consisted of monomer PRL, but the macroprolactinemia group was consisted of big PRL. The 2 groups′ PRL before the treatment had no statistical significance (P>0.05).After the treatment,the PRL concentrations of genuine HPRL group were high than those of macroprolactinemia group (P<0.05). The 2 groups′ monomer PRL concentrations before PEG precipitation treatment and GFC had no statistical significance (P>0.05), and the correlation was good [correlation coefficient (r)=0.844, P<0.05]. Conclusions PEG precipitation treatment for the detection of MRPL has good correlation with GFC, and it is economical and convenient. It is recommended as the routine screening method.

Key words: Prolactin, Macroprolactin, Hyperprolactinemia, Polyethylene glycol, Gel filtration chromatography